@ -14,10 +14,16 @@ Create "Node status" which returns "degraded" if the peer is gone
Common queries;
* SELECT a.job_uuid, b.host_name, a.job_command, a.job_data, a.job_progress, a.job_status FROM jobs a, hosts b WHERE a.job_host_uuid = b.host_uuid AND a.job_progress != 100;
* SELECT a.host_name, b.file_name, c.file_location_active FROM hosts a, files b, file_locations c WHERE a.host_uuid = c.file_location_host_uuid AND b.file_uuid = c.file_location_file_uuid ORDER BY b.file_name ASC, a.host_name ASC;
* SELECT a.dr_link_uuid, b.host_name, c.anvil_name, a.dr_link_note FROM dr_links a, hosts b, anvils c WHERE a.dr_link_host_uuid = b.host_uuid AND a.dr_link_anvil_uuid = c.anvil_uuid ORDER BY c.anvil_name ASC, b.host_name ASC;
* SELECT a.storage_group_uuid, d.storage_group_member_uuid, b.anvil_name, a.storage_group_name, c.host_name, d.storage_group_member_vg_uuid, d.storage_group_member_note FROM storage_groups a, anvils b, hosts c, storage_group_members d WHERE a.storage_group_uuid = d.storage_group_member_storage_group_uuid AND a.storage_group_anvil_uuid = b.anvil_uuid AND c.host_uuid = d.storage_group_member_host_uuid ORDER BY a.storage_group_name ASC, c.host_name ASC;
* SELECT a.scan_hardware_uuid, b.host_name, a.scan_hardware_cpu_cores AS cores, a.scan_hardware_cpu_threads AS threads, pg_size_pretty(a.scan_hardware_ram_total) AS ram_total, pg_size_pretty(a.scan_hardware_memory_total) AS memory_total, pg_size_pretty(a.scan_hardware_memory_free) AS memory_free FROM scan_hardware a, hosts b WHERE a.scan_hardware_host_uuid = b.host_uuid ORDER BY b.host_name ASC;
* SELECT a.scan_apc_ups_name AS name, a.scan_apc_ups_serial_number AS sn, a.scan_apc_ups_health AS health, a.scan_apc_ups_nmc_serial_number AS nmc_sn, a.scan_apc_ups_nmc_mac_address AS mac, a.scan_apc_ups_ip AS ip, b._percentage_charge AS charge, d.scan_apc_ups_battery_temperature AS btemp FROM scan_apc_upses a, scan_apc_ups_input b, scan_apc_ups_output c, scan_apc_ups_batteries d WHERE a.scan_apc_ups_uuid = b.scan_apc_ups_input_scan_apc_ups_uuid AND a.scan_apc_ups_uuid = c.scan_apc_ups_output_scan_apc_ups_uuid AND a.scan_apc_ups_uuid = d.scan_apc_ups_battery_scan_apc_ups_uuid ORDER BY name ASC;
* SELECT b.host_name, a.network_interface_uuid, a.network_interface_mac_address AS mac, a.network_interface_name AS name, a.network_interface_speed AS speed, a.network_interface_link_state AS link, a.network_interface_operational AS op, a.network_interface_duplex AS duplex, a.network_interface_medium AS medium, a.network_interface_bond_uuid AS bond_uuid, a.network_interface_bridge_uuid AS bridge_uuid FROM network_interfaces a, hosts b WHERE a.network_interface_host_uuid = b.host_uuid AND b.host_name LIKE 'an-a02%' AND a.network_interface_operational != 'DELETED' ORDER BY b.host_name ASC, a.network_interface_name ASC;
* SELECT b.host_name, a.bond_uuid, a.bond_name, a.bond_mode, a.bond_mtu AS mtu, a.bond_primary_interface AS primary, a.bond_active_interface AS active, a.bond_mac_address AS mac, a.bond_operational AS op, c.bridge_name, a.modified_date FROM bonds a, hosts b, bridges c WHERE a.bond_host_uuid = b.host_uuid AND a.bond_bridge_uuid = c.bridge_uuid AND (b.host_uuid = 'b4e46faf-0ebe-e211-a0d6-00262d0ca874' OR b.host_uuid = '4ba42b4e-9bf7-e311-a889-899427029de4') ORDER BY b.host_name ASC, a.bond_name ASC;
* SELECT b.host_name, a.bridge_uuid, a.bridge_name, a.bridge_id, a.bridge_mtu FROM bridges a, hosts b WHERE a.bridge_host_uuid = b.host_uuid AND b.host_name LIKE 'an-a02%' ORDER BY b.host_name ASC, a.bridge_name ASC;
* SELECT a.host_name, b.file_name, c.file_location_active FROM hosts a, files b, file_locations c WHERE a.host_uuid = c.file_location_host_uuid AND b.file_uuid = c.file_location_file_uuid ORDER BY b.file_name ASC, a.host_name ASC;
* SELECT b.host_name, a.health_agent_name, a.health_source_name, a.health_source_weight FROM health a, hosts b WHERE b.host_uuid = a.health_host_uuid AND b.host_name LIKE 'an-a02%' order by b.host_name ASC, a.health_agent_name ASC, a.health_source_weight ASC;
for lv in $(lvscan | grep deploy| awk '{print $2}' | sed s/\'//g); do lvremove -y $lv; done; rm -f /etc/drbd.d/an-test-deploy*; lvscan; ls -lah /etc/drbd.d/
- Remove this; (step 2) "This is the user name that you will log into Striker as and the name of the user that owns the database"
- Being set to the gateway, not the default DNS - "This is the domain name server(s) to use when resolving domain names. You can specify 2 or more, separated by commas."
- The web UI password isn't being set properly during Striker stage-2 setup
- Changing the password doesn't log out active webui sessions.
su - postgres -c "dropdb anvil" && su - postgres -c "createdb --owner admin anvil" && su - postgres -c "psql anvil < /var/lib/pgsql/anvil.out"
su postgres -c "psql anvil"
SELECT a.scan_apc_ups_name AS name, a.scan_apc_ups_serial_number AS sn, a.scan_apc_ups_health AS health, a.scan_apc_ups_nmc_serial_number AS nmc_sn, a.scan_apc_ups_nmc_mac_address AS mac, a.scan_apc_ups_ip AS ip, b._percentage_charge AS charge, d.scan_apc_ups_battery_temperature AS btemp FROM scan_apc_upses a, scan_apc_ups_input b, scan_apc_ups_output c, scan_apc_ups_batteries d WHERE a.scan_apc_ups_uuid = b.scan_apc_ups_input_scan_apc_ups_uuid AND a.scan_apc_ups_uuid = c.scan_apc_ups_output_scan_apc_ups_uuid AND a.scan_apc_ups_uuid = d.scan_apc_ups_battery_scan_apc_ups_uuid ORDER BY name ASC;
============
dnf -y install augeas
Jenkins;
Initial setup:
@ -1076,8 +1066,8 @@ OS10# write memory
### Set hostname:
OS10# configure terminal
OS10(config)# hostname zo-switch02
zo-switch02(config)#
OS10(config)# hostname an-switch02
an-switch02(config)#
======] VLT Config [=======
@ -1111,7 +1101,7 @@ OS10# show vlt 1 mismatch
(If no issues, VLT is OK)
# See how I am and my role (* == switch you're on)
zo-switch02(config)# show vlt 1 role
an-switch02(config)# show vlt 1 role
VLT Unit ID Role
------------------------
* 1 secondary
@ -1126,31 +1116,31 @@ OS10(conf-if-ma-1/1/1)# ip address 10.201.1.2/16
OS10(conf-if-ma-1/1/1)# no shutdown
OS10(conf-if-ma-1/1/1)# exit
OS10(config)# write memory
OS10(config)# hostname zo-switch01
zo-switch01(config)# interface vlan 100
zo-switch01(conf-if-vl-100)# description BCN1
zo-switch01(config)# exit
zo-switch01(conf-if-vl-100)# interface range ethernet 1/1/1-1/1/14
an-switch01(conf-range-eth1/1/15-1/1/24)# no shutdown
an-switch01(conf-range-eth1/1/15-1/1/24)# exit
an-switch01(config)# show vlan
Codes: * - Default VLAN, M - Management VLAN, R - Remote Port Mirroring VLANs,
@ - Attached to Virtual Network, P - Primary, C - Community, I - Isolated
Q: A - Access (Untagged), T - Tagged
@ -1164,12 +1154,12 @@ Q: A - Access (Untagged), T - Tagged
300 Active IFN1 T Po1000
A Eth1/1/15-1/1/24
4094 Active T Po1000
zo-switch01(config)# write memory
an-switch01(config)# write memory
### Delete a VLAN:
zo-switch02(config)# no interface vlan 3400
zo-switch02(config)# show vlan
an-switch02(config)# no interface vlan 3400
an-switch02(config)# show vlan
=== Firmware Update ===
@ -1251,7 +1241,7 @@ reboot: machine restart
### NOTE: The login prompt will appear before the system is ready to log in. The default username and password revert to 'admin' / 'admin', but this won't work for the first couple of minutes.
## OLD
zo-switch02# show version
an-switch02# show version
Dell EMC Networking OS10 Enterprise
Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved.
May 02 13:35:21 zo-a01n02.zennioptical.com setroubleshoot[5333]: SELinux is preventing /usr/sbin/drbdsetup from create access on the netlink_generic_socket labeled drbd_t. For complete SELinux messages run: sealert -l 4079c288-db4a-4f44-a588-94f1dbfff269
May 02 13:35:21 zo-a01n02.zennioptical.com setroubleshoot[5333]: SELinux is preventing /usr/sbin/drbdsetup from create access on the netlink_generic_socket labeled drbd_t.
May 02 13:35:21 an-a01n02.zennioptical.com setroubleshoot[5333]: SELinux is preventing /usr/sbin/drbdsetup from create access on the netlink_generic_socket labeled drbd_t. For complete SELinux messages run: sealert -l 4079c288-db4a-4f44-a588-94f1dbfff269
May 02 13:35:21 an-a01n02.zennioptical.com setroubleshoot[5333]: SELinux is preventing /usr/sbin/drbdsetup from create access on the netlink_generic_socket labeled drbd_t.
If you believe that drbdsetup should be allowed create access on netlink_generic_socket labeled drbd_t by default.