Broadcom (LSI) RAID controller scan agent using the 'storcli64' or 'perccli64' tool.
Found: [#!variable!count!#] controller(s).
The thermal sensor named: [#!variable!sensor_name!#], on: [#!variable!sensor_host!#] has not changed.
A new Broadcom (AVAGO/LSI) Storage controller has been found.
- Model: ....... [#!variable!model!#]
- Serial Number: [#!variable!serial_number!#]
- Cache Size: .. [#!variable!say_cache_size!#]
- Alarm State: . [#!variable!alarm_state!#]
Other detected variables:
- #!variable!name!#: [#!variable!value!#]
A new Broadcom (AVAGO/LSI) Storage controller Battery Backup Unit (BBU) has been found.
- On Controller: .... [#!variable!on_controller!#]
- Model: ............ [#!variable!model!#]
- Serial Number: .... [#!variable!serial_number!#]
- Type: ............. [#!variable!type!#]
- State: ............ [#!variable!state!#]
- Design Capacity: .. [#!variable!design_capacity!#]
- Manufacture Date: . [#!variable!manufacture_date!#] (yyyy/mm/dd)
- Replacement Needed? [#!variable!replacement_needed!#]
Other detected variables:
A new Broadcom (AVAGO/LSI) Storage controller Virtual Drive (VD) has been found.
- On Controller: .... [#!variable!on_controller!#]
- ID String: ........ [#!variable!id_string!#]
- Creation Date: .... [#!variable!creation_date!#]
- Data Protection: .. [#!variable!data_protection!#]
- Disk Cache Policy: [#!variable!disk_cache_policy!#]
- Emulation Type: ... [#!variable!emulation_type!#]
- Encryption: ....... [#!variable!encryption!#]
- Blocks: ........... [#!variable!blocks!#]
- Strip Size: ....... [#!variable!strip_size!#]
- Drives Per Span: .. [#!variable!drives_per_span!#]
- Span Depth: ....... [#!variable!span_depth!#]
- SCSI NAA ID: ...... [#!variable!scsi_naa_id!#] (https://en.wikipedia.org/wiki/ISCSI#Addressing)
Other detected variables:
A new Broadcom (AVAGO/LSI) Storage controller Drive Group (DG) has been found.
- On Controller: ............. [#!variable!on_controller!#]
- ID String: ................. [#!variable!id_string!#]
- Access: .................... [#!variable!access!#]
- RAID Level: ................ [#!variable!raid_type!#]
- Array Size: ................ [#!variable!array_size!#]
- Array State: ............... [#!variable!array_state!#]
- Consistent: ................ [#!variable!consistent!#]
- Write Cache: ............... [#!variable!write_cache!#]
- Read Cache: ................ [#!variable!read_cache!#]
- Disk Cache: ................ [#!variable!disk_cache!#]
- CacheCade: ................. [#!variable!cachecade!#]
- Scheduled Consistency Check: [#!variable!scheduled_cc!#]
- Raw Cache String: .......... [#!variable!cache!#]
Other detected variables:
A new Physical Drive, connected to a Broadcom (AVAGO/LSI) Storage controller, has been found.
- On Controller: ....... [#!variable!on_controller!#]
- Virtual Drive: ....... [#!variable!virtual_drive!#]
- Drive Group: ......... [#!variable!drive_group!#]
- Vendor: .............. [#!variable!vendor!#]
- Model: ............... [#!variable!model!#]
- Serial Number: ....... [#!variable!serial_number!#]
- Capacity: ............ [#!variable!size!#]
- Sector Size: ......... [#!variable!sector_size!#]
- Self-Encrypting Drive? [#!variable!self_encrypting_drive!#]
Other detected variables:
A new Broadcom (AVAGO/LSI) Storage controller Cachevault (FBU) has been found.
- On Controller: .... [#!variable!on_controller!#]
- Model: ............ [#!variable!model!#]
- Serial Number: .... [#!variable!serial_number!#]
- Type: ............. [#!variable!type!#]
- State: ............ [#!variable!state!#]
- Design Capacity: .. [#!variable!design_capacity!#]
- Manufacture Date: . [#!variable!manufacture_date!#]
- Replacement Needed? [#!variable!replacement_needed!#]
Other detected variables:
The temperature of the physical drive: [#!variable!serial_number!#] has risen above the critical temperature of: [#!variable!high_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the physical drive: [#!variable!serial_number!#] has risen above the warning temperature of: [#!variable!high_warning_temperature!# °C]. It will go critical at: [#!variable!high_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the physical drive: [#!variable!serial_number!#] has dropped below the critical temperature of: [#!variable!low_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the physical drive: [#!variable!serial_number!#] has dropped the warning temperature of: [#!variable!low_warning_temperature!# °C]. It will go critical at: [#!variable!low_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the physical drive: [#!variable!serial_number!#] is above the critical temperature of: [#!variable!high_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!value!# °C]
The temperature of the physical drive: [#!variable!serial_number!#] is above the warning temperature of: [#!variable!high_warning_temperature!# °C]. It will go critical at: [#!variable!high_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!value!# °C]
The temperature of the physical drive: [#!variable!serial_number!#] is below the critical temperature of: [#!variable!low_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!value!# °C]
The temperature of the physical drive: [#!variable!serial_number!#] is below the warning temperature of: [#!variable!low_warning_temperature!# °C]. It will go critical at: [#!variable!low_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!value!# °C]
The temperature of the physical drive: [#!variable!serial_number!#] has risen back into a safe temperature range.
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the physical drive: [#!variable!serial_number!#] has risen back above the critical low threshold, but it is still in a warning state. It will be marked clear when it rises above: [#!variable!low_warning_temperature!#].
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the physical drive: [#!variable!serial_number!#] has jumped more than: [#!variable!jump!# °C] since the last scan.
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the physical drive: [#!variable!serial_number!#] has fallen back into a safe temperature range.
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the physical drive: [#!variable!serial_number!#] has dropped back below the critical high threshold, but it is still in a warning state. It will be marked clear when it drops below: [#!variable!high_warning_temperature!#].
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the physical drive: [#!variable!serial_number!#] has dropped more than: [#!variable!jump!# °C] since the last scan.
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the RAID controller: [#!variable!serial_number!#] is above the high critical temperature of: [#!variable!high_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!value!# °C]
The temperature of the RAID controller: [#!variable!serial_number!#] is above the high warning temperature of: [#!variable!high_warning_temperature!# °C]. It will go critical at: [#!variable!high_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!value!# °C]
The temperature of the RAID controller: [#!variable!serial_number!#] is below the low critical temperature of: [#!variable!low_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!value!# °C]
The temperature of the RAID controller: [#!variable!serial_number!#] is below the low warning temperature of: [#!variable!low_warning_temperature!# °C]. It will go critical at: [#!variable!low_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!value!# °C]
The temperature of the RAID controller: [#!variable!serial_number!#] has risen above the high critical temperature of: [#!variable!high_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the RAID controller: [#!variable!serial_number!#] has risen above the high warning temperature of: [#!variable!high_warning_temperature!# °C]. It will go critical at: [#!variable!high_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the RAID controller: [#!variable!serial_number!#] has risen back into a safe temperature range.
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the RAID controller: [#!variable!serial_number!#] has risen back above the critical low threshold, but it is still in a warning state. It will be marked clear when it rises above: [#!variable!low_warning_temperature!#].
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the RAID controller: [#!variable!serial_number!#] has jumped more than: [#!variable!jump!# °C] since the last scan.
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the RAID controller: [#!variable!serial_number!#] has dropped below the critical temperature of: [#!variable!low_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the RAID controller: [#!variable!serial_number!#] has dropped the warning temperature of: [#!variable!low_warning_temperature!# °C]. It will go critical at: [#!variable!low_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the RAID controller: [#!variable!serial_number!#] has fallen back into a safe temperature range.
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the RAID controller: [#!variable!serial_number!#] has dropped back below the critical high threshold, but it is still in a warning state. It will be marked clear when it drops below: [#!variable!high_warning_temperature!#].
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the RAID controller: [#!variable!serial_number!#] has dropped more than: [#!variable!jump!# °C] since the last scan.
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Cachevault (FBU): [#!variable!serial_number!#] is above the critical temperature of: [#!variable!high_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!value!# °C]
The temperature of the Cachevault (FBU): [#!variable!serial_number!#] is above the warning temperature of: [#!variable!high_warning_temperature!# °C]. It will go critical at: [#!variable!high_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!value!# °C]
The temperature of the Cachevault (FBU): [#!variable!serial_number!#] is below the critical temperature of: [#!variable!low_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!value!# °C]
The temperature of the Cachevault (FBU): [#!variable!serial_number!#] is below the warning temperature of: [#!variable!low_warning_temperature!# °C]. It will go critical at: [#!variable!low_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!value!# °C]
The temperature of the Cachevault (FBU): [#!variable!serial_number!#] has risen above the critical temperature of: [#!variable!high_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Cachevault (FBU): [#!variable!serial_number!#] has risen above the warning temperature of: [#!variable!high_warning_temperature!# °C]. It will go critical at: [#!variable!high_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Cachevault (FBU): [#!variable!serial_number!#] has risen back into a safe temperature range.
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Cachevault (FBU): [#!variable!serial_number!#] has risen back above the critical low threshold, but it is still in a warning state. It will be marked clear when it rises above: [#!variable!low_warning_temperature!#].
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Cachevault (FBU): [#!variable!serial_number!#] has jumped more than: [#!variable!jump!# °C] since the last scan.
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Cachevault (FBU): [#!variable!serial_number!#] has dropped below the critical temperature of: [#!variable!low_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Cachevault (FBU): [#!variable!serial_number!#] has dropped the warning temperature of: [#!variable!low_warning_temperature!# °C]. It will go critical at: [#!variable!low_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Cachevault (FBU): [#!variable!serial_number!#] has fallen back into a safe temperature range.
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Cachevault (FBU): [#!variable!serial_number!#] has dropped back below the critical high threshold, but it is still in a warning state. It will be marked clear when it drops below: [#!variable!high_warning_temperature!#].
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Cachevault (FBU): [#!variable!serial_number!#] has dropped more than: [#!variable!jump!# °C] since the last scan.
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Battery Backup Unit (BBU): [#!variable!serial_number!#] is above the critical temperature of: [#!variable!high_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!value!# °C]
The temperature of the Battery Backup Unit (BBU): [#!variable!serial_number!#] is above the warning temperature of: [#!variable!high_warning_temperature!# °C]. It will go critical at: [#!variable!high_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!value!# °C]
The temperature of the Battery Backup Unit (BBU): [#!variable!serial_number!#] is below the critical temperature of: [#!variable!low_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!value!# °C]
The temperature of the Battery Backup Unit (BBU): [#!variable!serial_number!#] is below the warning temperature of: [#!variable!low_warning_temperature!# °C]. It will go critical at: [#!variable!low_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!value!# °C]
The temperature of the Battery Backup Unit (BBU): [#!variable!serial_number!#] has risen above the critical temperature of: [#!variable!high_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Battery Backup Unit (BBU): [#!variable!serial_number!#] has risen above the warning temperature of: [#!variable!high_warning_temperature!# °C]. It will go critical at: [#!variable!high_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Battery Backup Unit (BBU): [#!variable!serial_number!#] has risen back into a safe temperature range.
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Battery Backup Unit (BBU): [#!variable!serial_number!#] has risen back above the critical low threshold, but it is still in a warning state. It will be marked clear when it rises above: [#!variable!low_warning_temperature!#].
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Battery Backup Unit (BBU): [#!variable!serial_number!#] has jumped more than: [#!variable!jump!# °C] since the last scan.
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Battery Backup Unit (BBU): [#!variable!serial_number!#] has dropped below the critical temperature of: [#!variable!low_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Battery Backup Unit (BBU): [#!variable!serial_number!#] has dropped the warning temperature of: [#!variable!low_warning_temperature!# °C]. It will go critical at: [#!variable!low_critical_temperature!# °C]!:
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Battery Backup Unit (BBU): [#!variable!serial_number!#] has fallen back into a safe temperature range.
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Battery Backup Unit (BBU): [#!variable!serial_number!#] has dropped back below the critical high threshold, but it is still in a warning state. It will be marked clear when it drops below: [#!variable!high_warning_temperature!#].
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
The temperature of the Battery Backup Unit (BBU): [#!variable!serial_number!#] has dropped more than: [#!variable!jump!# °C] since the last scan.
- #!variable!name!#: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
- The temperature of the physical drive: [#!variable!serial_number!#] has changed: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
- The temperature of the Cachevault (FBU): [#!variable!serial_number!#] has changed: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
- The temperature of the BBU: [#!variable!serial_number!#] has changed: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
- The temperature of the controller: [#!variable!serial_number!#] has changed: [#!variable!old_value!# °C] -> [#!variable!new_value!# °C]
- The Virtual Drive: [#!variable!id_string!#]: is performing a background initialization, which is now: [#!variable!new_value!#] complete.
- The Virtual Drive: [#!variable!id_string!#]: has completed its background initialization operation.
- Controller: [#!variable!serial_number!#]: '#!variable!name!#' has changed: [#!variable!old_value!#] -> [#!variable!new_value!#]
NOTE: This is expected and is no reason for concern.
While processing data from adapter: [#!variable!adapter!#], which has the serial number: [#!variable!serial_number!#], the drive in virtual drive: [#!variable!virtual_disk!#] in the enclosure: [#!variable!enclosure_id!#] at slot number: [#!variable!slot_number!#] in span: [#!variable!span!#] at row: [#!variable!row!#] initially was found in drive group: [#!variable!old_drive_group!#] but the variable 'Drive position' reports it as being in drive group: [#!variable!new_drive_group!#]. This might be a program error in parsing the output of: [#!variable!shell_call!#]. Please report this error along with the output of that shell call so that we can improve this scan agent.
The RAID controller's properties have changed:
- Model: ....... [#!variable!old_model!#] -> [#!variable!new_model!#]
- Serial Number: [#!variable!old_serial_number!#] -> [#!variable!new_serial_number!#]
- Cache Size: .. [#!variable!old_say_cache_size!#] -> [#!variable!new_say_cache_size!#]
- Alarm State: . [#!variable!old_alarm_state!#] -> [#!variable!new_alarm_state!#]
- Controller: [#!variable!serial_number!#]: '#!variable!name!#' has changed: [#!variable!old_value!#] -> [#!variable!new_value!#]
- Controller: [#!variable!serial_number!#]: New variable found; #!variable!name!#: [#!variable!value!#]
Processed an invalid drive group: [#!variable!drive_group!#] from the line: [#!variable!line!#]!
- Controller: [#!variable!serial_number!#]: '#!variable!name!#' has returned: [#!variable!new_value!#]
- Controller: [#!variable!serial_number!#]: '#!variable!name!#' has vanished!
The controller: [#!variable!model!#] with the serial number: [#!variable!serial_number!#] has vanished!
The RAID controller has returned:
- Model: ....... [#!variable!new_model!#]
- Serial Number: [#!variable!new_serial_number!#]
- Cache Size: .. [#!variable!new_say_cache_size!#]
- Alarm State: . [#!variable!new_alarm_state!#]
The RAID controller's Battery Backup Unit (BBU) properties have changed:
- On Controller: .... [#!variable!old_on_controller!#] -> [#!variable!new_on_controller!#]
- Model: ............ [#!variable!old_model!#] -> [#!variable!new_model!#]
- Serial Number: .... [#!variable!old_serial_number!#] -> [#!variable!new_serial_number!#]
- Type: ............. [#!variable!old_type!#] -> [#!variable!new_type!#]
- State: ............ [#!variable!old_state!#] -> [#!variable!new_state!#]
- Design Capacity: .. [#!variable!old_design_capacity!#] -> [#!variable!new_design_capacity!#]
- Manufacture Date: . [#!variable!old_manufacture_date!#] -> [#!variable!new_manufacture_date!#] (yyyy/mm/dd)
- Replacement Needed? [#!variable!old_replacement_needed!#] -> [#!variable!new_replacement_needed!#]
The RAID controller's Battery Backup Unit (BBU) has returned:
- On Controller: .... [#!variable!old_on_controller!#] -> [#!variable!new_on_controller!#]
- Model: ............ [#!variable!old_model!#] -> [#!variable!new_model!#]
- Serial Number: .... [#!variable!old_serial_number!#] -> [#!variable!new_serial_number!#]
- Type: ............. [#!variable!old_type!#] -> [#!variable!new_type!#]
- State: ............ [#!variable!old_state!#] -> [#!variable!new_state!#]
- Design Capacity: .. [#!variable!old_design_capacity!#] -> [#!variable!new_design_capacity!#]
- Manufacture Date: . [#!variable!old_manufacture_date!#] -> [#!variable!new_manufacture_date!#] (yyyy/mm/dd)
- Replacement Needed? [#!variable!old_replacement_needed!#] -> [#!variable!new_replacement_needed!#]
- The BBU: [#!variable!serial_number!#]: '#!variable!name!#' changed: [#!variable!old_value!#] -> [#!variable!new_value!#]
- The BBU: [#!variable!serial_number!#]: '#!variable!name!#' has returned: [#!variable!new_value!#]
- The BBU: [#!variable!serial_number!#]: '#!variable!name!#' has vanished!
- A new variable was found on the BBU: [#!variable!serial_number!#] = [#!variable!value!#]
- The BBU: [#!variable!bbu_serial_number!#] on the RAID controller: [#!variable!controller_serial_number!#] has vanished!
The RAID controller's Virtual Drive (VD) properties have changed:
- On Controller: .... [#!variable!old_on_controller!#] -> [#!variable!new_on_controller!#]
- ID String: ........ [#!variable!old_id_string!#] -> [#!variable!new_id_string!#]
- Creation Date: .... [#!variable!old_creation_date!#] -> [#!variable!new_creation_date!#]
- Data Protection: .. [#!variable!old_data_protection!#] -> [#!variable!new_data_protection!#]
- Disk Cache Policy: [#!variable!old_disk_cache_policy!#] -> [#!variable!new_disk_cache_policy!#]
- Emulation Type: ... [#!variable!old_emulation_type!#] -> [#!variable!new_emulation_type!#]
- Encryption: ....... [#!variable!old_encryption!#] -> [#!variable!new_encryption!#]
- Blocks: ........... [#!variable!old_blocks!#] -> [#!variable!new_blocks!#]
- Strip Size: ....... [#!variable!old_strip_size!#] -> [#!variable!new_strip_size!#]
- Drives Per Span: .. [#!variable!old_drives_per_span!#] -> [#!variable!new_drives_per_span!#]
- Span Depth: ....... [#!variable!old_span_depth!#] -> [#!variable!new_span_depth!#]
- SCSI NAA ID: ...... [#!variable!old_scsi_naa_id!#] -> [#!variable!new_scsi_naa_id!#]
The RAID controller's Virtual Drive (VD) has returned:
- On Controller: .... [#!variable!old_on_controller!#] -> [#!variable!new_on_controller!#]
- ID String: ........ [#!variable!old_id_string!#] -> [#!variable!new_id_string!#]
- Creation Date: .... [#!variable!old_creation_date!#] -> [#!variable!new_creation_date!#]
- Data Protection: .. [#!variable!old_data_protection!#] -> [#!variable!new_data_protection!#]
- Disk Cache Policy: [#!variable!old_disk_cache_policy!#] -> [#!variable!new_disk_cache_policy!#]
- Emulation Type: ... [#!variable!old_emulation_type!#] -> [#!variable!new_emulation_type!#]
- Encryption: ....... [#!variable!old_encryption!#] -> [#!variable!new_encryption!#]
- Blocks: ........... [#!variable!old_blocks!#] -> [#!variable!new_blocks!#]
- Strip Size: ....... [#!variable!old_strip_size!#] -> [#!variable!new_strip_size!#]
- Drives Per Span: .. [#!variable!old_drives_per_span!#] -> [#!variable!new_drives_per_span!#]
- Span Depth: ....... [#!variable!old_span_depth!#] -> [#!variable!new_span_depth!#]
- SCSI NAA ID: ...... [#!variable!old_scsi_naa_id!#] -> [#!variable!new_scsi_naa_id!#]
- The Virtual Drive: [#!variable!id_string!#]: '#!variable!name!#' changed: [#!variable!old_value!#] -> [#!variable!new_value!#]
- The Virtual Drive: [#!variable!id_string!#]: '#!variable!name!#' has returned: [#!variable!new_value!#]
- The Virtual Drive: [#!variable!id_string!#]: '#!variable!name!#' has vanished!
- A new variable was found on the Virtual Drive: [#!variable!id_string!#] = [#!variable!value!#]
The Virtual Drive: [#!variable!id_string!#] on the RAID controller: [#!variable!controller_serial_number!#] has vanished!
The RAID controller's Drive Group (DG) properties have changed:
- ID String: ................. [#!variable!old_id_string!#] -> [#!variable!new_id_string!#]
- Access: .................... [#!variable!old_access!#] -> [#!variable!new_access!#]
- RAID Level: ................ [#!variable!old_raid_type!#] -> [#!variable!new_raid_type!#]
- Array Size: ................ [#!variable!old_array_size!#] -> [#!variable!new_array_size!#]
- Array State: ............... [#!variable!old_array_state!#] -> [#!variable!new_array_state!#]
- Consistent: ................ [#!variable!old_consistent!#] -> [#!variable!new_consistent!#]
- Write Cache: ............... [#!variable!old_write_cache!#] -> [#!variable!new_write_cache!#]
- Read Cache: ................ [#!variable!old_read_cache!#] -> [#!variable!new_read_cache!#]
- Disk Cache: ................ [#!variable!old_disk_cache!#] -> [#!variable!new_disk_cache!#]
- CacheCade: ................. [#!variable!old_cachecade!#] -> [#!variable!new_cachecade!#]
- Scheduled Consistency Check: [#!variable!old_scheduled_cc!#] -> [#!variable!new_scheduled_cc!#]
- Raw Cache String: .......... [#!variable!old_cache!#] -> [#!variable!new_cache!#]
The RAID controller's Drive Group (DG) has returned:
- ID String: ................. [#!variable!old_id_string!#] -> [#!variable!new_id_string!#]
- Access: .................... [#!variable!old_access!#] -> [#!variable!new_access!#]
- RAID Level: ................ [#!variable!old_raid_type!#] -> [#!variable!new_raid_type!#]
- Array Size: ................ [#!variable!old_array_size!#] -> [#!variable!new_array_size!#]
- Array State: ............... [#!variable!old_array_state!#] -> [#!variable!new_array_state!#]
- Consistent: ................ [#!variable!old_consistent!#] -> [#!variable!new_consistent!#]
- Write Cache: ............... [#!variable!old_write_cache!#] -> [#!variable!new_write_cache!#]
- Read Cache: ................ [#!variable!old_read_cache!#] -> [#!variable!new_read_cache!#]
- Disk Cache: ................ [#!variable!old_disk_cache!#] -> [#!variable!new_disk_cache!#]
- CacheCade: ................. [#!variable!old_cachecade!#] -> [#!variable!new_cachecade!#]
- Scheduled Consistency Check: [#!variable!old_scheduled_cc!#] -> [#!variable!new_scheduled_cc!#]
- Raw Cache String: .......... [#!variable!old_cache!#] -> [#!variable!new_cache!#]
- The Drive Group: [#!variable!id_string!#]: '#!variable!name!#' changed: [#!variable!old_value!#] -> [#!variable!new_value!#]
- The Drive Group: [#!variable!id_string!#]: '#!variable!name!#' has returned: [#!variable!new_value!#]
- The Drive Group: [#!variable!id_string!#]: '#!variable!name!#' has vanished!
The Physical Drive (PD) properties have changed:
- On Controller: ....... [#!variable!old_on_controller!#] -> [#!variable!new_on_controller!#]
- Virtual Drive: ....... [#!variable!old_virtual_drive!#] -> [#!variable!new_virtual_drive!#]
- Drive Group: ......... [#!variable!old_drive_group!#] -> [#!variable!new_drive_group!#]
- Enclosure ID: ........ [#!variable!old_enclosure_id!#] -> [#!variable!new_enclosure_id!#]
- Slot Number: ......... [#!variable!old_slot_number!#] -> [#!variable!new_slot_number!#]
- Vendor: .............. [#!variable!old_vendor!#] -> [#!variable!new_vendor!#]
- Model: ............... [#!variable!old_model!#] -> [#!variable!new_model!#]
- Serial Number: ....... [#!variable!old_serial_number!#] -> [#!variable!new_serial_number!#]
- Capacity: ............ [#!variable!old_size!#] -> [#!variable!new_size!#]
- Sector Size: ......... [#!variable!old_sector_size!#] -> [#!variable!new_sector_size!#]
- Self-Encrypting Drive? [#!variable!old_self_encrypting_drive!#] -> [#!variable!new_self_encrypting_drive!#]
The Physical Drive (PD) has returned:
- On Controller: ....... [#!variable!old_on_controller!#] -> [#!variable!new_on_controller!#]
- Virtual Drive: ....... [#!variable!old_virtual_drive!#] -> [#!variable!new_virtual_drive!#]
- Drive Group: ......... [#!variable!old_drive_group!#] -> [#!variable!new_drive_group!#]
- Enclosure ID: ........ [#!variable!old_enclosure_id!#] -> [#!variable!new_enclosure_id!#]
- Slot Number: ......... [#!variable!old_slot_number!#] -> [#!variable!new_slot_number!#]
- Vendor: .............. [#!variable!old_vendor!#] -> [#!variable!new_vendor!#]
- Model: ............... [#!variable!old_model!#] -> [#!variable!new_model!#]
- Serial Number: ....... [#!variable!old_serial_number!#] -> [#!variable!new_serial_number!#]
- Capacity: ............ [#!variable!old_size!#] -> [#!variable!new_size!#]
- Sector Size: ......... [#!variable!old_sector_size!#] -> [#!variable!new_sector_size!#]
- Self-Encrypting Drive? [#!variable!old_self_encrypting_drive!#] -> [#!variable!new_self_encrypting_drive!#]
- The Physical Drive (PD): [#!variable!serial_number!#]: '#!variable!name!#' changed: [#!variable!old_value!#] -> [#!variable!new_value!#]
- The Physical Drive (PD): [#!variable!serial_number!#]: '#!variable!name!#' has returned: [#!variable!new_value!#]
- A new variable was found on the Physical Drive (PD): [#!variable!serial_number!#] = [#!variable!value!#]
- Physical Drive: [#!variable!serial_number!#]: '#!variable!name!#' has vanished!
- The Physical Drive: [#!variable!physical_disk_serial_number!#] on the RAID controller: [#!variable!controller_serial_number!#] has vanished!
The RAID controller's Cachevault (FBU) properties have changed:
- On Controller: .... [#!variable!old_on_controller!#] -> [#!variable!new_on_controller!#]
- Model: ............ [#!variable!old_model!#] -> [#!variable!new_model!#]
- Serial Number: .... [#!variable!old_serial_number!#] -> [#!variable!new_serial_number!#]
- Type: ............. [#!variable!old_type!#] -> [#!variable!new_type!#]
- State: ............ [#!variable!old_state!#] -> [#!variable!new_state!#]
- Design Capacity: .. [#!variable!old_design_capacity!#] -> [#!variable!new_design_capacity!#]
- Manufacture Date: . [#!variable!old_manufacture_date!#] -> [#!variable!new_manufacture_date!#] (yyyy/mm/dd)
- Replacement Needed? [#!variable!old_replacement_needed!#] -> [#!variable!new_replacement_needed!#]
The RAID controller's Cachevault (FBU) has returned:
- On Controller: .... [#!variable!old_on_controller!#] -> [#!variable!new_on_controller!#]
- Model: ............ [#!variable!old_model!#] -> [#!variable!new_model!#]
- Serial Number: .... [#!variable!old_serial_number!#] -> [#!variable!new_serial_number!#]
- Type: ............. [#!variable!old_type!#] -> [#!variable!new_type!#]
- State: ............ [#!variable!old_state!#] -> [#!variable!new_state!#]
- Design Capacity: .. [#!variable!old_design_capacity!#] -> [#!variable!new_design_capacity!#]
- Manufacture Date: . [#!variable!old_manufacture_date!#] -> [#!variable!new_manufacture_date!#] (yyyy/mm/dd)
- Replacement Needed? [#!variable!old_replacement_needed!#] -> [#!variable!new_replacement_needed!#]
- The Cachevault (FBU): [#!variable!serial_number!#]: '#!variable!name!#' changed: [#!variable!old_value!#] -> [#!variable!new_value!#]
- The Cachevault (FBU): [#!variable!serial_number!#]: '#!variable!name!#' has returned: [#!variable!new_value!#]
- The Cachevault (FBU): [#!variable!serial_number!#]: '#!variable!name!#' has vanished!
- A new variable was found on the Cachevault (FBU): [#!variable!serial_number!#] = [#!variable!value!#]
- The Cachevault (FBU): [#!variable!cachevault_serial_number!#] on the RAID controller: [#!variable!controller_serial_number!#] has vanished!
- The Drive Group: [#!variable!id_string!#]: '#!variable!name!#' has been found: [#!variable!new_value!#]
- The Physical Drive (PD): [#!variable!serial_number!#]: '#!variable!name!#' changed: [#!variable!old_value!#] -> [#!variable!new_value!#]
If this ticks up by '1', and this hasn't changed recently before, it is generally safe to ignore.
However, if the error count jumps by more than one, or increments more than once a month, or climbs above 5 or 6, then the drive may be in the early stages of failing.
If this is the case and your hardware vendor allows for pre-failure replacement, you may with to request a replacement.
- The Physical Drive (PD): [#!variable!serial_number!#]: '#!variable!name!#' changed: [#!variable!old_value!#] -> [#!variable!new_value!#]
The error counters generally shouldn't change. Please investigate the cause of the error and replace the drive, if necessary.
NOTE: Unless another alert indicates otherwise, the drive has *not* failed.
- The RAID controller: [#!variable!serial_number!#]: '#!variable!name!#' changed: [#!variable!old_value!#] -> [#!variable!new_value!#]
Correctable errors should be very rare, and though they don't pose an immediate threat, should be investigated as soon as possible.
- The RAID controller: [#!variable!serial_number!#]: '#!variable!name!#' changed: [#!variable!old_value!#] -> [#!variable!new_value!#]
Uncorrectable errors are likely an indication that the controller is failing.
Please contact your hardware vendor and plan to replace the controller at your earliest opportunity.
Servers should be migrated to the peer as soon as possible.
- The RAID controller: [#!variable!serial_number!#]: '#!variable!name!#' changed: [#!variable!old_value!#] -> [#!variable!new_value!#]
The severity of this alert depends on the new state. if the new state is 'Optimal', then there is no cause for concern.
Most other states are likely worth investigating as soon as possible as the controller state should never change under normal conditions.
- The BBU: [#!variable!serial_number!#]: '#!variable!name!#' changed: [#!variable!old_value!#] -> [#!variable!new_value!#]
The battery should never go into an over-charge state. This may indicate the pack is about to fail.
Please investigate and replace, if necessary, at your earliest convenience.
NOTE: If the pack fails, write performance will be impacted!
- The BBU: [#!variable!serial_number!#]: '#!variable!name!#' changed: [#!variable!old_value!#] -> [#!variable!new_value!#]
If there is a known over temperature event, then this may indicate that the battery has heated up along with other components.
If the battery pack is the only device to get hot, then it may indicate that the pack is failing.
Please investigate and replace, if necessary, at your earliest convenience.
NOTE: If the pack fails, write performance will be impacted!
- The BBU: [#!variable!serial_number!#]: '#!variable!name!#' changed: [#!variable!old_value!#] -> [#!variable!new_value!#]
Please investigate and replace, if necessary, at your earliest convenience.
NOTE: If the pack fails, write performance will be impacted!
- The RAID controller: [#!variable!serial_number!#] is in the database: [#!variable!count!#] times. This shouldn't happen.
NOTE: Existing controller information will be purged. The installed controller (if it still exists) will be in detected
and recorded in the comming scan.
The 'storcli64' program was not found at: [#!variable!path!#], exiting.
The 'storcli64' program was found at: [#!variable!path!#], but it is not executable. exiting.
No LSI-based RAID controllers were found, exiting.
#!free!#
#!free!#
Failed to find the serial number for the adapter: [#!variable!adapter!#]. Please check the output of '#!data!path::storcli64!# #!data!sys::arguments::controller_info!#' and look for the 'Serial Number = X' string. Exiting.
The battery backup unit (BBU) with the serial number: [#!variable!serial_number!#] didn't have a reported host controller serial number. This is probably a program error, sorry about that.
The controller with serial number: [#!variable!serial_number!#] could not be converted to a controller UUID. This is probably a program error, sorry about that.
The Cachevault (FBU) with the serial number: [#!variable!serial_number!#] didn't have a reported host controller serial number. This is probably a program error, sorry about that.
The virtual drive (VD) with the ID string: [#!variable!id_string!#] didn't have a reported host controller serial number. This is probably a program error, sorry about that.
The drive group (DG) with the ID string: [#!variable!id_string!#] didn't have a reported host controller serial number. This is probably a program error, sorry about that.
The physical drive (PV) with the serial number: [#!variable!serial_number!#] didn't have a reported host controller serial number. This is probably a program error, sorry about that.
Failed to find the serial number for the physical drive (PV) in the virtual drive: [#!variable!virtual_drive!#] and drive group: [#!variable!drive_group!#] in enclosure: [#!variable!enclosure_id!#] in slot: [#!variable!slot_number!#]. This is probably a program error, sorry about that.
Old UUID for drive group: [#!variable!drive_group!#] found. This is likely a program error.
Controller UUID for the drive group with UUID: [#!variable!drive_group_uuid!#] not found. This is likely a program error.
Non-numeric value in a numeric variable; virtual drive blocks: [#!variable!virtual_drive_blocks!#], drives per span: [#!variable!drives_per_span!#], or span depth: [#!variable!span_depth!#]. This is likely a program error.
Starting #!string!scan_storcli_brand_0001!#:
Bytes
Hours
Hour
Minutes
Minute
Seconds
Second
N/A
Always Write-Back
Write-Back
Write-Through
Sectors
Gbps
Access Policy
Alarm
Allow Boot With Preserved Cache?
Allow Controller Encryption?
Allow Mixed Redundancy On An Array?
Any Offline VD Cache Preserved?
One Or More Premium Features Enabled?
Autodetect Backplane
Automatic Rebuild
Backend Port Count
Background Initialization Rate (Percent)
Battery Relearn Interval
Battery Warning Enabled
BBU/FBU Connected?
BBU/FBU Status
BBU/FBU Supported?
Virtual Drives Presented to BIOS
Controller BIOS Version
Failed To Detect Controller BIOS At Boot?
Controller Boot Block Version
Boot Volume Capable?
Boot Volume Supported?
Controller Boot Loader Version
Mainboard BUS Number
Cachevault (FBU) Flash Size
Controller ASIC Revision
Controller Cluster Active?
Controller Cluster Permitted?
Controller Cluster Supported?
User Configurable "Abort Consistency Check on Error"?
User Configurable "Alarm Control"?
User Configurable "Background Initialization Rate"?
User Configurable "Block SSD Write Disk Cache Change"?
User Configurable "Consistency Check Rate"?
User Configurable "Patrol Read Rate"?
User Configurable "Rebuild Rate"?
User Configurable "Reconstruction Rate"?
Consistency Check Rate (Percent)
Consistency Check Interval
Controller Number
Controller Has Booted Into Safe-Mode?
Controller Reboot Required For Security Operation?
Controller Status
Cachecade Size
Current Size Of Firmware Cache
Dedicated Hot-Spare Supported?
Dedicated Hot-Spare Limited?
Automatic Enhanced Import Default Setting
Break Mirror RAID Support Default Setting
Write-Back Caching With Bad BBU/FBU Default Setting
Cached IO Enabled By Default
Default Coercion Mode Setting
Direct Physical Disk Mapping Default Setting
Dirty Activity LED Default Setting
Disable "Human Interface Infrastructure (HII)" Default Setting
Disable "Join Mirror" Default Setting
Disable "Online Reset Controller To Defaults" Default Setting
Disable "Puncturing" Default Setting
"Enable Crash Dump" Default Setting
"Enable LED Header" Default Setting
Logical Device Bad Block Management Enabled By Default
Enable Shield State Default Setting
Expose Enclosure Device Default Setting
Drive Activity LED Enabled By Default
Maintain Physical Disk Fail History Default Setting
Maximum Chained Enclosures Default Setting
Physical Layer Polarity Default Setting
Physical Layer Polarity Split Default Setting
Power Saving Option Default Setting
Default Read Policy
Restore Hot-Spare On Physical Disk Insertion Default Setting
Default SMART Mode
Default Disk Spin-Down Time
Default Strip Size
"Terminal Log In Flash" Default Setting
"Treat Single Span RAID 1E As RAID 10" Default Setting
Default Uncertified Hard Disk Drive Policy
Default Virtual Drive Power Save Policy
Default Write Cache Policy
Default "Zero-Based Enclosure Enumeration" Policy
Default Zero-Channel RAID Configuration
Delay Between Spin-Up Groups
Delay during POST (seconds)
Deny "Clear"?
Deny "Consistency Check"?
Deny "Force Failed"?
Deny "Force Good/Bad"?
Deny "Missing Replace"?
Deny "Physical Disk Locate"?
Deny "SCSI Pass-Through"?
Deny "SATA Tunneling Protocol Pass-Through"?
Deny "Serial Management Protocol Pass-Through"?
Deny "Virtual Drive Locate"?
Controller Interface
Controller Device Number
Direct-Connect Drives Spun-Up Per Minute
Disable "Online Controller Reset Policy"?
Disable "Premium Feature Key (PFK) Change"?
Virtual Drive Cache Policy Supported?
Drive Coercion Mode
Number Of Drive Groups
Linux Driver
Linux Driver Version
ECC Bucket Count
ECC Bucket Leak Rate
ECC Bucket Size
Enable BIOS?
Enable 'Ctrl + R' Utility?
Enable JBOD Arrays?
Enable Pre-boot Command Line Interface?
Enable WebBIOS Utility?
Expose Enclosure Device Policy?
Extended Logical Device Supported?
Failed To Get Lock Key On Bootup?
Firmware Package Build
Firmware Version
Flash Size
Flush Time
Force Offline Supported?
Force Online Supported?
Force Rebuild Supported?
Foreign Config Import Supported?
Front-End (External) Port Count
Function Number
Timestamps in GMT?
Global Hot Spares Supported?
Headless Mode Supported?
Controller to Mainboard Interface
Image Name Pending Write
User-Configurable IO Policy?
Load Balancing Mode
Lock Key Assigned?
Lock Key Has Not Been Backed Up?
Maintain Physical Disk Fail History Policy
Controller Manufacture Date
Maximum Arms Per Virtual Drive
Maximum Number Of Arrays
Maximum Configurable Cachecade Size
Maximum Data Transfer Size
Maximum Number of Drives To Spin-Up At A Time
Maximum Number Of Virtual Drives
Maximum Number Of Parallel Commands
Maximum Scatter-Gather Element Count
Maximum Spans Per Virtual Drive
Maximum Strip Size
Maximum Strips Per IO
Maximum Transportable Virtual Drives
Maximum Virtual Drives Per Array
Memory Correctable Error Count
Memory Uncorrectable Error Count
Minimum Strip Size
Mix Drive Types In Enclosure?
Mixing SAS and SATA Platter-Based Drives In Virtual Drive?
Mixing SAS and SATA Solid State Drives In Virtual Drive?
Mixing SSDs And HDDs In Virtual Drive
Controller Model
Physical Disk Native Command Queuing Supported?
Next Schedule Battery Learn Cycle Start
Next Consistency Check Start
Next Patrol Read Start
NV Data Version
NV RAM Size
Controller OEM Identification
On-Board Expander?
On-Board RAM Size
Patrol Read Rate (Percent)
Patrol Read Interval
PCI Bus Address
Virtual Drive Performance Metrics Supported?
Performance Mode
Point In Time Progress?
Power Saving?
Preboot Command Line Interface Utility Version
RAID Levels Supported
Real-Time Scheduler?
Rebuild Rate (Percent)
Virtual Drive Reconstruction Supported?
Optimize/Reorder Host Requests?
Restore Hot-Spare on Insertion?
Hot-Spares Can Be Reverted?
Controller Rework Date
Roll-Back Operation In Progress
Safe ID
SAS Address
SAS Disabled?
Security Key Assigned?
Security Subsystem Class Policy Is Write-Back?
Self-Diagnostics Supported?
Serial Debugger?
Set Power State For Configuration?
Snapshot Enabled?
Spanning Supported?
Spin-Down Mode
Stop BIOS On Error?
Sub-Device ID
Sub-Vendor ID
Support Allowed Operations?
Boot-Time Premium Feature Key Change Supported?
Break Mirror Supported?
Support Complex Programmable Logic Device (CPLD) Update?
Support Configure Auto-Balance?
Support Configure Page Model?
Support Diagnostics Results?
Support Disable Immediate IO?
Support Discard Cache During Logical Disk Delete?
Support Drive Activity LED Settings?
Support Emergency Spares?
Support Emulated Spares?
Support Enclosure Enumeration?
Support Enhanced Foreign Configuration Import?
Support External Enclosures?
Support External Security Key Management?
Support "Fast Path" Premium Feature?
Support "Flush Write Verify"?
Support Force Flash?
Support Forcing 512-Byte Emulated Sector Sizes?
Support JBOD Arrays?
Support JBOD Write-Cache?
Large IO Supported?
Large Queue Depth Supported?
Support Logical Device Bad Block Management Information?
Support Logical Disk Protection Information, Type 1
Support Logical Disk Protection Information, Type 2
Support Logical Disk Protection Information, Type 3
"Maintenance Mode" Supported?
Support "Maximum Rate SATA"?
Support More Than 8 Physical Layers?
Support Multipath?
Support Odd And Even Drive Count In RAID 1E?
Performance Tuning Supported?
Physical Disk Firmware Download Supported?
Maximum Power Save With Cache Supported?
Power Save Supported?
Premium Feature Keys Supported?
Support "Protection Information"?
Support "Reset Now"?
Support SCSI Enclosure Service Monitoring?
Support Security?
Support Security On JBOD?
Support Security Subsystem Class Association?
Support Security Subsystem Class Write-Back?
Support Setting Link Speed?
Support Shield State?
Support SSD Patrol Read?
Support Suspect/Resume of Background Operations?
Support T10 Power States?
Temperature Supported?
Support Online Capacity Expansion Without Adding Drives?
Support Uneven Spans?
Support Virtual Drive Cache Bypass?
Support Virtual Drive Discard Cache During Logical Disk Deletion?
Support "Virtual Drive Hide"?
Supported Drive Types?
Temperature Sensor For Controller?
Temperature Sensor For "RAID On Chip" (ROC) Processor?
Topology Type
Trusted Platform Module (TPM)
Upgradable Complex Programmable Logic Device (CPLD)
Upgrade Key
Use Drive Activity LED For Locate?
Vendor ID
Virtual Drive Read Policy
Virtual Drive Write Policy
WebBIOS Version
RAID On Chip (ROC) Temperature
Absolute State Of Charge (Percent)
Application Data
Automatic Learning Mode
Automatic Learning Interval
Average Time To Empty
Average Time To Full
Battery Backup Charge (Hold-Up) Time
Battery Field Replaceable Unit (FRU) Number
Battery Missing?
Battery State
"Cache Offload" Premium Feature Required?
Charger System Controller
Charger System State
Charging Current
Charging Status
Charging Terminated?
Current
Charge/Discharge Cycle Count
Date Manufactured
Design Capacity
Design Voltage
Battery Chemistry
Device Name
Discharging?
Full Charge Capacity
Fully Charged?
Fully Discharged?
i2c Errors Detected?
Initialized?
Learn Cycle Active?
Learn Cycle Requested?
Learn Cycle Status
Learn Cycle Timeout?
Learn Cycle Delay Interval
Manufacturer Model Name
Maximum Errors
Module Microcode Update Required?
Next Scheduled Learn Cycle
No Space To Cache Offload?
Over Charged?
Over Temperature?
Battery Unit Is About To Fail?
Battery Unit Statistics Configuration
Learn Cycle Required?
Relative State Of Charge
Remaining Capacity
Remaining Capacity Alarm
Remaining Capacity Low?
Remaining Time Alarm?
Remaining Time Alarm Threshold
Replacement Required?
Runtime To Empty
Specification Information
Temperature Status
Terminate Discharge Alarm?
Transparent Learn
Type
Voltage Status
Capacitance (Percent)
Cachevault Pack Energy
Remaining Reserve Space
TMM Field Replaceable Unit Number
Active Operations
Creation Date
Creation Time
Data Protection?
Emulation Type
Encryption
Exposed To The Operating System?
Logical Disk Is Ready For Operating System Requests?
Number Of Blocks
Number Of Drives Per Span
On Controller With Serial Number
SCSI Network Address Authority (NAA) ID
Span Depth
Strip Size
Initial Write-Cache Setting
Access
Array Size
Array State
Raw Cache Value String
Cachecade Enabled?
Consistent?
Disk Cache
RAID Type
Read Cache
Scheduled Consistency Check?
Write Cache
Bad Block Management (BBM) Error Count
Vendor Certified Drive?
Coerced Size
Commissioned Spare?
Connected Port Number
Connector Name
Device ID
Drive Link Speed
Drive Type
Drive Model Number
Drive Capacity
Emergency Spare?
Enclosure Position
Firmware Release Number
Firmware Revision
Interface Type
Last "Predictive Failure" Event Sequence Number
Interface Link Speed
Drive Is Locked?
Drive Manufacturer
Media Error Count
Drive Model Number
Flash (NAND) Vendor
Needs External Key Management Attention?
Non-Coerced Size
"Other" Error Count
Predictive Failure Count
Protection Information
Protection Information Eligible?
Raw Size
Row
SAS Port #0 Interface Speed
SAS Port #0 Port Status
SAS Port #0 SAS Address
SAS Port #1 Interface Speed
SAS Port #1 Port Status
SAS Port #1 SAS Address
Sector Size
Drive Encrypted?
Self-Encrypting Drive (SED) Capable?
Self-Encrypting Drive (SED) Enabled?
Self-Encrypting Drive (SED)?
Sequence Number
Drive Serial Number
Shield Counter
SMART Alert Flagged By Drive?
Span
Spun-Up?
State
Successful Diagnostics Completion On Date?
Wide Port Capable?
World Wide Name (WWN)
Drive's Temperature