* Updated anvil-manage-server-storage, striker-collect-debug, and striker-update-cluster to be able to find a connection on an interface when none were found on preferred networks.
Signed-off-by: digimer <mkelly@alteeve.ca>
* Updated DRBD->get_status() to take the new 'host' paramter to allow the caller to define the hash key string used in the stored data.
* Updated Get->anvil_version() (and a few other places) to use the new 'striker-ui-api' shell user, replacing the 'apache' user.
* Updated Remote->test_access() to take the new 'close' parameter to close the SSH session used when testing access to the target.
* Fixed a logging bug in anvil-manage-power.
* Updated anvil-update-system to take the '--no-reboot' and 'clear-cache' command line switches.
Signed-off-by: digimer <mkelly@alteeve.ca>
* Updated anvil-manage-server-storage to the point where it can now insert and eject optical disks!
* Updated System->call to log parameters if 'shell_call' isn't set.
* Fixed a bug in anvil-manage-server process_interactive where an $anvil->data reference was being scoped.
Signed-off-by: digimer <mkelly@alteeve.ca>
* To update file handling for the new DR host linking mechanism, file_locations -> file_location_anvil_uuid was changed to file_location_host_uuid.
This required a fair number of changes elsewhere to handle this, with a particular noted change to Database->get_anvils() to look at host_uuid's for the subnodes in an Anvil! and, if either is marked as needing a file, make sure the peer is as well. Similarly, any linked DRs are set to have the file as well.
* Created a new Network->find_access that simply takes a target host name or UUID, and it returns a list of networks and IPs that the target can be accessed by.
* Updated Network->load_ips() to find the network interface being used for traffic so that things like the interface speed can be recorded, even when an IP is on a bridge or bond.
Unrelated, but in this commit, is a restoration of calling scan agents with a timeout now that the virsh hang issue has been resolved.
Signed-off-by: digimer <mkelly@alteeve.ca>
* Created the anvil-manage-dr man page.
* Reworked anvil-manage-dr's --protect logic to search for which network works with the DR host, instead of assuming it's the SN.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Reworked Network->bridge_info() to use 'ip' to get the list of bridges, and 'bridge' to find interfaces connected to the bridge.
* Added 'test' messages to Words->string().
* Fixed a bug in scan-lvm where mdadm based PVs didn't read the sector size properly.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Fixed a bug in scancore-agents/Makefile.am where scan-network was missing.
* Started work on anvil-delete-server.8. Incomplete at this time.
* Updated Network->get_ips() to record the interface status.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Added multiple new private methods to Network that help in managing the firewall.
* Updated Server->boot_server to manage the firewall after the server boots. Updated ->migrate_server to create a job, if a database connection exists, for the migration target to update it's firewall as soon after the server appears as possible.
* Updated ocf:server:alteeve to manage the firewall when called post-migration, in case there was no DB connection and the job above didn't run. Fixed a bug where the disk state wasn't being evaluated properly.
* Updated scan-server to check that the firewall is managed when a server state has changed.
* Updated anvil-daemon to run Network->manage_firewall on startup.
* Heavily reworked 'anvil-manage-server' to either just run 'Network->manage_firewall', or if passed '--server X', to wait for the server to appear for up to 1 minute, then to check that the firewall is managed (to capture servers being migrated to the host.)
* Removed firewall management from striker-prep-database.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Updated Database->get_host_from_uuid() to cache results.
* Fixed a bug in Database->get_storage_group_data where a DELETE wasn't deleting from the history schema as well.
* In Database->resync_databases(), references to the old 'host_uuid' that we used to use to resync just the local host's data was removed. Added also a check where two or more entries in a given history schema had the same modified_date and, when found, the newest entry is preserved and the rest are deleted. Before this, a resync where two+ records had the same modified_time would only sync the last record, leaving a mismatch in history schema entries triggering repeated resyncs.
* Fixed a bug in Email->send_alerts() where the 'alerts' table was being updated without a modified_date being set.
* Fixed a bug in System->test_ipmi() where the 'hosts' table was being updated without a modified_date being set.
* Updated scan-network to clear up old deleted ip_addresses, bonds and bridges. Also fixed bugs where public schema records were being deleted without history records being deleted.
* Updated anvil-update-states to fix bugs where DELETEs were happening without setting the modified_date.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Updated Network->load_ips() to load extra information about the interfaces.
* Updated ocf:alteeve:server to not check libvirtd daemon state on server start.
* Updated scan-hardware to check for duplicate entries and purge if found.
* Updated scan-network to check for the 'default' virbr0 interface by checking if the config file exists instead of calling virsh.
* Updated scan-server to have better logging.
* Created the new (and incomplete) anvil-test-alerts tool
* Updated scancore to support --purge to pass to all agents and then exit.
* Updated ScanCore->call_scan_agents() to no longer use 'timeout' as it was causing issues with virsh calls.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Updated ocf:alteeve:server to always try to bring up the peer's DRBD resource, even when the local resource is up.
* Fixed a bug in scan-network where purging duplicate bridges failed in some cases.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Updated Network->find_matches() to take 'source' and 'line' parameters to help identify the source of issues with missing hashes.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Created Network->is_our_interface() which returns '1' if an interface is one managed by an Anvil!. Also updated scan-network to use this to determine when an interface alert should be a warning or notice level alert.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Updated scan-filesystems to set swap usage alerts to notice level only.
* Updated scan-network to pull the permanent MAC address from an 'ethtool -P <iface>' call to deal with the fact that wireless interfaces don't have their real MAC in the sysfs address file.
* Updated anvil-provision-server to set the rtc_tickpolicy to catchup.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Updated Jobs->get_job_uuid() to accept the new 'incomplete' parameter that, when set, will look for jobs whose progress is > 1 and < 100.
* Updated ScanCore-agent_startup() to take the new 'no_db_ok' parameter which returns with '0' if no DB is available and that parameter is set to '1'.
* Fixed a logging bug in 'anvil-join-anvil'.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Updated anvil-configure-host to not reboot on network chane (will verify when this commit is function tested).
Signed-off-by: Digimer <digimer@alteeve.ca>
* Added the 'print' parameter to Log->variables() to allow printing to STDOUT when set.
* Renamed Network->check_bonds() to Network->check_networks() in anticipation of adding bridge monitoring / repair to it later.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Upped the aging of jobs and alerts data from 2 to 24 hours. Also added a check to prevent deleting a job of any age that is incomplete.
* Major update to anvil-configure-host to not touch the network unless something has actually changed. Not yet tested on a fresh system, will verify nothing broke in the CI tests this commit will trigger. Also changed it so that, if after reconfiguring the network it times out trying to reconnect to a database, it calls a reboot instead of simply exiting. Further, a reboot is now not called on exit unless something changed to require it.
* Updated Network->check_bonds() to return '1' if anything was done to heal a bond.
* Updated anvil-update-states to be more careful about clearing virsh bridges. Specifically, it checks to see if virsh is running and that the returned bridges aren't actually error codes.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Updated anvil-daemon to call Network->check_bonds() with 'all' on startup, then woth 'down_only' once per minute to try to heal down'ed bonds.
* Updated anvil-watch-bonds to take a 'run-once' switch and exit after one report, if set.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Updated Database->archive_table() and ->_find_behind_databases() to loop through connected databases, instead of configured databases.
* Updated Network->get_ips() to only record the real MAC addresses on network interfaces (not bonds or bridges) in the "network::${host}::interface::${in_iface}::mac_address" hash. This should help avoid reboot loops caused by anvil-configure-host thinking the network needs to be reconfigured when it doesn't actually need to be.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Updated the scan agent timeout to 60 seconds. Also made the scan agent exit code log entries more helpful.
* Updated System->collect_ipmi_data() to now better handle duplicate sensor names. Now, instead of simply appending an integer, we find the hex address and use that in the sensor name when duplicates exist. This solves the problem of the sensor names not being consistently shown in order.
* Fixed message bugs (bad variable insertions) in scan-apc-pdu and scan-apc-ups.
* Fixed schema procedure bugs in the 'temperature' and 'ip_address' tables where the columns were in bad order, causing constanty updates.
Incomplete work;
* Create the shell of 'anvil-manage-storage', but virtually no logic exists in it yet.
* Started work on anvil-safe-start to deal with an issue where DRBD resources don't start when a server is running on a peer.
Signed-off-by: Digimer <digimer@alteeve.ca>
* The get_mmeory endpoint was completed.
* The get_replicated_storage endpoint was completed, though it requires testing and likely has issues.
To prepare for the get_status endpoint work, I needed to update ScanCore and modules to track the host_status. This commit contains the work needed for this.
* Updated ScanCore->post_scan_analysis_striker() to use configured fence devices (except PDUs) to check if a target host is off or on, in there is no host_ipmi interface. In all cases, if a machine can be confirmed on or off, the host_status is now updated.
* To support the above fence based power checks, updated scan-cluster to store the on-disk CIB in the new scan_cluster -> scan_cluster_cib colume.
* Updated ScanCore->parse_cib() to map stonith primitive IDs to fence agents. Updated ->parse_crm_mon() to not call if the executable doesn't exist to avoid unhelpful error messages in the logs when called from a Striker.
* Update DRBD->gather_data() to get the size data from /sys/block/drbd<minor>/size' x '/sys/block/drbd<minor>/queue/logical_block_size so it works when a device is Secondary (and can't be promoted).
* Updated Database->get_hosts_info() to record the short host name as well as the stored host name. Created ->update_host_status() as a wrapper to ->insert_or_update_hosts() that only updates the host status.
* Updated anvil-join-anvil to disabled ksm and ksmtuned daemons.
* Updated scancore and anvil-daemon to set the host_status to 'online' on startup.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Fixed a bug in Remote->call() where the output of the call not ending in a newline wasn't having the return code parsed off properly.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Finished DRBD->get_next_resource() that returns the next available minor and the next free TCP port (with two free ports available after it).
* Created Storage->get_storage_group_details() that pulls together the LVM, storage group members and storage groups into one block of data.
* Made more progress on tools/anvil-provision-server. It now gets up to the point of creating LVs, creating DRBD resource files, loading them, creating metadata and up'ing the resource. It doesn't yet (successfully) force a new resource to primary.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Created the new method Cluster->get_primary_host_uuid() that returns the 'host_uuid' of the primary node in the given cluster. This is useful for external programs to figure out which node is primary. Example is provisioning a new server being assigned to the active node. Also created ->is_primary() that is a similar test to see if the active node is the primary node or not.
* Updated Cluster->parse_cib() and ->parse_crm_mon() to work on remote hosts.
* Updated Database->get_hosts() to store the short host names.
* Created Get->host_from_ip_address() that translates an IP address to a host_uuid and host_name, if it's an IP assigned currently to a known host.
* Created Network->find_target_ip() that simplifies finding which IP address to use when the caller wants to connect to a target host.
* Reworked the anvil-join-anvil to parse fence_arguments in a way that handles passwords with spaces in them.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Created Database->get_power() that loads data from the special 'power' table.
* Fixed a bug in calls to Network->ping() where some weren't formatted properly for receiving two string variables.
* Updated Database->get_anvils() to record the machine types when recording host information.
* Updated Database->get_hosts_info() to also load the 'host_ipmi' column.
* Updated Database->get_upses() to store the link to the 'power' -> 'power_uuid', when available.
* Created ScanCore->call_scan_agents() that does the work of actually calling scan agents, moving the logic out from the scancore daemon.
* Created ScanCore->check_power() that takes a host and the anvil it is in and returns if it's on batteries or not. If it is, the time on batteries and estimate hold-up time is returned. If not, the highest charge percentage is returned.
* Created ScanCore->post_scan_analysis() that is a wrapper for calling the new ->post_scan_analysis_dr(), ->post_scan_analysis_node() and ->post_scan_analysis_striker(). Of which, _dr and _node are still empty, but _striker is complete.
** ->post_scan_analysis_striker() is complete. It now boots a node after a power loss if the UPSes powering it are OK (at least one has mains power, and the main-powered UPS(es) have reached the minimum charge percentage). If it's thermal, IPMI is called and so long as at least one thermal sensor is found and it/they are all OK, it is booted. For now, M2's thermal reboot delay logic hasn't been replicated, as it added a lot of complexity and didn't prove practically useful.
* Created System->collect_ipmi_data() and moved 'scan_ipmitool's ipmitool call and parse into that method. This was done to allow ScanCore->post_scan_analysis_striker() to also call IPMI on a remote machine during thermal down events without reimplementing the logic.
* Updated scan-ipmitool to only record temperature data for data collected locally. Also renamed 'machine' variables and hash keys to 'host_name' to clarify what is being stored.
* Updated scancore to clear the 'system::stop_reason' variable.
* Added missing packages to striker-manage-install-target.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Created 'Cluster->which_node' that returns 'node1' or 'node2' to indicate which node a host is.
* Continued working on scan_cluster; decided to make it not host-dependent.
Signed-off-by: Digimer <digimer@alteeve.ca>
* More work done on Email->send_email() to, well, actually send email (which it isn't doing yet, but it's close).
* Updated Words->key() to include the bad key name when no entry for the requested key exists in the words.xml file.
Signed-off-by: Digimer <digimer@alteeve.ca>