* Updated Cluster->add_server() to now set failure timeouts to actual numbers instead of INFINITY after discovering that INFINITY doesn't work in those cases.
* Updated Databsae->get_hosts to now check if other entries have the same host name, and if so, to set their host_key to 'DELETED'. This should make it easier to handle when a hardware machine is replaced by new hardware but uses the same host_name.
* Updated Email->check_queue() to start and enable postfix.service if it's found to not be running.
* Updated Get->available_resources() to return '!!no_data!!' when a given host hasn't got any data in scan_lvm_vgs. Now use this in anvil-provision-server to exit if a node or dr host hasn't run scancore yet.
* Fixed a bug in scan-lvm where the pvs_uuid wasn't being loaded properly, preventing lost PVs, VGs and LVs from being flagged as deleted.
* Started work on anvil-migate-server, though it's far from complete.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Fixed a bug in Cluster->shutdown_server() where the wrong variable was being evaluated when checking the server state.
* Created DRBD->delete_resource() that deletes a resource's backing device and configuration. Note that this wipes the DRBD MD and and FS signatures before removing the LV. Updated DRBD->gather_data() to record the backing devices for volumes.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Fixed a bug in Cluster->parse_cib() when a server that is off wasn't setting 'status'.
* Renamed 'server::location::<server>::host' to '...::host_name' in several places.
* Got more work done on anvil-delete-server, up to the point where it calls the new Cluster->delete_server() method.
* Updated fence_pacemaker to call 'drbdadm adjust all' to dampen an issue where in-memory fence configs seem to change, preventing reconnection of the peer after it reboots from the fence. More testing needed on this issue.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Removed the exit-if-no-DB check in ocf:alteeve:server so that (hopefully, needs testing), running servers won't be impacted if the nodes lost contact with both/all strikers.
* Updated scan-server to make an explicit check for missing XML definition files on startup and write them if needed.
* Very beginning work on anvil-delete-server has been started.
* Updated anvil-provision-server to wait when it's running in peer mode until the new XML definition is in the DB and then write it out to disk before exiting. Also updated it to add the new server to pacemaker before exiting.
Signed-off-by: Digimer <digimer@alteeve.ca>