* In Cluster->parse_cib(), added parsers for node attributes and resource rules. Also stored the existence of and details of each under the server resources for easier referencing.
* Updated scan-server to check for / add DRBD fence rules as needed.
Scancore APC agent bugs;
* For clarity, converted all '#!no_value!#' and '#!no_connection!#' to use '!!' instead in APC scan agents.
* Fixed a bug to set/clear alerts related to phases disappearing to deal with concurrent logins from different hosts triggering false phase loss alerts.
* Fixed missing variables not being passed to alerts/log entries.
Started more work on anvil-manage-server, but on hold again while the DRBD fencing work is completed.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Got anvil-manage-alerts managing alert overrides.
* Created, but for now commented out, the new 'audit' table.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Created Get->anvil_from_switch and Get->server_from_switch() (both need testing) that takes a string that could be either a name or UUID, figures out which it is, finds the entry in the DB and started the X_uuid and X_name switch variables.
* Started work on a second attempt at anvil-manage-server.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Updated striker-initialize-host to support calls from command line switches, and wrote the man page for it.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Created DRBD->check_proxy_license() to do (some level of) sanity checks on the DRBD proxy license file.
* Updated DRBD->gather_data() to parse out the inside and outside ports for resource configs using proxy.
* Reworked DRBD->get_next_resource() to return 1, 3 or 7 TCP ports depending, with the new long_throw_ports parameter triggering the 7 ports.
* Added 'tcpdump' to the anvil-core requires list.
* Reworked scan-drbd to record the ports used in proxy configs. This required adding a check to change the 'scan_drbd_peer_tcp_port' column type to 'text' to support CSVs.
* Reworked anvil-manage-dr (needs testing!) to support "long-throw" DR configs.
* Updated anvil-safe-stop to check if the nodes are in the cluster before trying to migrate.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Updated anvil-safe-stop to check for VMs running, even if the cluster is stopped, when --stop-servers is used.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Created the anvil-manage-dr man page.
* Reworked anvil-manage-dr's --protect logic to search for which network works with the DR host, instead of assuming it's the SN.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Updated Server->parse_definition() to check if a failed 'virsh list' output was passed in. Also changed it to not exit if the XML can't be parsed.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Reworked Network->bridge_info() to use 'ip' to get the list of bridges, and 'bridge' to find interfaces connected to the bridge.
* Added 'test' messages to Words->string().
* Fixed a bug in scan-lvm where mdadm based PVs didn't read the sector size properly.
Signed-off-by: Digimer <digimer@alteeve.ca>
* Updated anvil-daemon to call anvil-manage-files on a per-minute basis to handle files added outside of the WebUI.
Signed-off-by: Digimer <digimer@alteeve.ca>