* Undid the #!no_value!# -> !!no_value!! change as it broke language processing.

* Fixed a bug in scan-apc-pdu that was preventing it from compiling.

Signed-off-by: Digimer <digimer@alteeve.ca>
main
Digimer 2 years ago
parent 33b4516dea
commit eae2ab4d9f
  1. 4
      Anvil/Tools/Convert.pm
  2. 4
      Anvil/Tools/Remote.pm
  3. 24
      scancore-agents/scan-apc-pdu/scan-apc-pdu
  4. 2
      scancore-agents/scan-apc-ups/scan-apc-ups

@ -848,8 +848,8 @@ sub format_mmddyy_to_yymmdd
date => $date,
}});
# Sometimes we're passed '--' or '!!no_value!!' which is not strictly an error, so we'll return it back.
if (($date eq "--") or ($date eq "!!no_value!!"))
# Sometimes we're passed '--' or '#!no_value!#' which is not strictly an error, so we'll return it back.
if (($date eq "--") or ($date eq "#!no_value!#"))
{
return($date);
}

@ -828,14 +828,14 @@ sub read_snmp_oid
output => $output,
return_code => $return_code,
}});
my $value = "!!no_value!!";
my $value = "#!no_value!#";
foreach my $line (split/\n/, $output)
{
$anvil->Log->variables({source => $THIS_FILE, line => __LINE__, level => $debug, list => { line => $line }});
if ($line =~ /No Response/i)
{
$value = "!!no_connection!!";
$value = "#!no_connection!#";
$anvil->Log->variables({source => $THIS_FILE, line => __LINE__, level => $debug, list => { value => $value }});
}
elsif (($line =~ /STRING: "(.*)"$/i) or ($line =~ /STRING: (.*)$/i))

@ -1176,20 +1176,22 @@ WHERE
# Have any outlets changed?
foreach my $scan_apc_pdu_outlet_number (sort {$a cmp $b} keys %{$anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu_outlets}})
{
my $scan_apc_pdu_serial_number = $anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_serial_number};
my $new_scan_apc_pdu_outlet_name = $anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu_outlets}{$scan_apc_pdu_outlet_number}{scan_apc_pdu_outlet_name};
my $new_scan_apc_pdu_outlet_on_phase = $anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu_outlets}{$scan_apc_pdu_outlet_number}{scan_apc_pdu_outlet_on_phase};
my $new_scan_apc_pdu_outlet_state = $anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu_outlets}{$scan_apc_pdu_outlet_number}{scan_apc_pdu_outlet_state};
$anvil->Log->variables({source => $THIS_FILE, line => __LINE__, level => 2, list => {
scan_apc_pdu_serial_number => $scan_apc_pdu_serial_number,
new_scan_apc_pdu_outlet_name => $new_scan_apc_pdu_outlet_name,
new_scan_apc_pdu_outlet_on_phase => $new_scan_apc_pdu_outlet_on_phase,
new_scan_apc_pdu_outlet_state => $new_scan_apc_pdu_outlet_state,
}});
if (($new_scan_apc_pdu_outlet_on_phase ne "!!no_connection!!") or ($new_scan_apc_pdu_outlet_on_phase ne "!!no_value!!"))
if (($new_scan_apc_pdu_outlet_on_phase ne "!!no_connection!!") or ($new_scan_apc_pdu_outlet_on_phase ne "#!no_value!#"))
{
$anvil->Alert->check_condition_age({clear => 1, name => "scan_apc_pdu::pdu::".$scan_apc_pdu_serial_number."::phase_lost::".$scan_apc_pdu_outlet_number});
}
if (($new_scan_apc_pdu_outlet_state eq "!!no_connection!!") or ($new_scan_apc_pdu_outlet_state eq "!!no_value!!"))
if (($new_scan_apc_pdu_outlet_state eq "!!no_connection!!") or ($new_scan_apc_pdu_outlet_state eq "#!no_value!#"))
{
$anvil->Alert->check_condition_age({clear => 1, name => "scan_apc_pdu::pdu::".$scan_apc_pdu_serial_number."::outlet_lost::".$scan_apc_pdu_outlet_number});
}
@ -1256,7 +1258,7 @@ WHERE
# Phase changed. If the new phase is '!!no_connection!!', it
# could be contention, so check if this has been the case for
# at least five minutes.
if (($new_scan_apc_pdu_outlet_on_phase eq "!!no_connection!!") or ($new_scan_apc_pdu_outlet_on_phase eq "!!no_value!!"))
if (($new_scan_apc_pdu_outlet_on_phase eq "!!no_connection!!") or ($new_scan_apc_pdu_outlet_on_phase eq "#!no_value!#"))
{
my $age = $anvil->Alert->check_condition_age({name => "scan_apc_pdu::pdu::".$scan_apc_pdu_serial_number."::phase_lost::".$scan_apc_pdu_outlet_number});
$anvil->Log->variables({source => $THIS_FILE, line => __LINE__, level => 2, list => { age => $age }});
@ -1288,7 +1290,7 @@ WHERE
if ($new_scan_apc_pdu_outlet_state ne $old_scan_apc_pdu_outlet_state)
{
# If we had a contention and the new value is '!!no_connection!!'.
if (($new_scan_apc_pdu_outlet_state eq "!!no_connection!!") or ($new_scan_apc_pdu_outlet_state eq "!!no_value!!"))
if (($new_scan_apc_pdu_outlet_state eq "!!no_connection!!") or ($new_scan_apc_pdu_outlet_state eq "#!no_value!#"))
{
my $age = $anvil->Alert->check_condition_age({name => "scan_apc_pdu::pdu::".$scan_apc_pdu_serial_number."::outlet_lost::".$scan_apc_pdu_outlet_number});
$anvil->Log->variables({source => $THIS_FILE, line => __LINE__, level => 2, list => { age => $age }});
@ -2126,7 +2128,7 @@ sub gather_pdu_data
"pdu::scan_apc_pdu_uuid::${scan_apc_pdu_uuid}::scan_apc_pdu::scan_apc_pdu_mac_address" => $anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_mac_address},
data_type => $data_type,
}});
if ($anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_mac_address} eq "!!no_value!!")
if ($anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_mac_address} eq "#!no_value!#")
{
# Some older PDUs use a different OID.
($anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_mac_address}, $data_type) = $anvil->Remote->read_snmp_oid({
@ -2163,7 +2165,7 @@ sub gather_pdu_data
"pdu::scan_apc_pdu_uuid::${scan_apc_pdu_uuid}::scan_apc_pdu::scan_apc_pdu_mtu_size" => $anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_mtu_size},
data_type => $data_type,
}});
if ($anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_mtu_size} eq "!!no_value!!")
if ($anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_mtu_size} eq "#!no_value!#")
{
# Some older PDUs use a different OID.
($anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_mtu_size}, $data_type) = $anvil->Remote->read_snmp_oid({
@ -2191,7 +2193,7 @@ sub gather_pdu_data
"pdu::scan_apc_pdu_uuid::${scan_apc_pdu_uuid}::scan_apc_pdu::scan_apc_pdu_link_speed" => $anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_link_speed},
data_type => $data_type,
}});
if ($anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_link_speed} eq "!!no_value!!")
if ($anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_link_speed} eq "#!no_value!#")
{
# Some older PDUs use a different OID.
($anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_link_speed}, $data_type) = $anvil->Remote->read_snmp_oid({
@ -2315,7 +2317,7 @@ sub gather_pdu_data
### Convert some unknown values to values we can store in the database
# MAC address
if ($anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_mac_address} eq "!!no_value!!")
if ($anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_mac_address} eq "#!no_value!#")
{
$anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_mac_address} = "xx:xx:xx:xx:xx:xx";
$anvil->Log->variables({source => $THIS_FILE, line => __LINE__, level => 2, list => {
@ -2323,7 +2325,7 @@ sub gather_pdu_data
}});
}
# MTU
if ($anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_mtu_size} eq "!!no_value!!")
if ($anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_mtu_size} eq "#!no_value!#")
{
$anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_mtu_size} = 0;
$anvil->Log->variables({source => $THIS_FILE, line => __LINE__, level => 2, list => {
@ -2331,7 +2333,7 @@ sub gather_pdu_data
}});
}
# Link speed
if ($anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_link_speed} eq "!!no_value!!")
if ($anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_link_speed} eq "#!no_value!#")
{
$anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu}{scan_apc_pdu_link_speed} = 0;
$anvil->Log->variables({source => $THIS_FILE, line => __LINE__, level => 2, list => {
@ -2339,7 +2341,7 @@ sub gather_pdu_data
}});
}
# Wattage isn't available on older PDUs
if ($anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu_variables}{total_wattage_draw} eq "!!no_value!!")
if ($anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu_variables}{total_wattage_draw} eq "#!no_value!#")
{
$anvil->data->{pdu}{scan_apc_pdu_uuid}{$scan_apc_pdu_uuid}{scan_apc_pdu_variables}{total_wattage_draw} = 0;
$anvil->Log->variables({source => $THIS_FILE, line => __LINE__, level => 2, list => {

@ -2070,7 +2070,7 @@ sub gather_ups_data
my ($anvil) = @_;
### TODO: If the network with the UPS is congested, it is possible that, despite connecting to the
### UPS, some OID reads may fail with '!!no_connection!!'. Try to read them a second time in
### UPS, some OID reads may fail with '#!no_connection!#'. Try to read them a second time in
### these cases. Regardless, be sure to check all returned OID values for 'no connection' and
### handle such cases more gracefully.